BM TRADA certified fire stopping, fire doors and compartmentation surveys for new build blocks, rented homes and converted flats across Stratford, East Village, Forest Gate, Canning Town and East Ham.
Our recent work includes West End theatres, a hotel at Liverpool Street, a live venue at Battersea Power Station and a TV studio in Acton. On every job, we plan noise, dust and access around the people using the building.
Each project brought challenges found in buildings right across London: historic fabric, busy occupants and fire lines broken by other trades. We photograph each seal before it is covered, then hand over certificates, datasheets and as-built drawings, so landlords, managing agents and fire risk assessors have proof the work was done.

Hospitality & Leisure
Covent Garden, London
Fire stopping at the Lyceum Theatre, Covent Garden: fire lines reinstated after a new fire alarm, every seal photographed for the theatre's records.
Read Case Study

Hospitality & Leisure
Strand, London
Fire stopping at the Savoy Theatre, Strand: alarm cabling breaches sealed and recorded for the theatre's next fire risk assessment.
Read Case Study
We work across all 32 London boroughs, from period conversions in central London to new build blocks and industrial sites further out. Find your area below to see how we can help.
CAMDEN, ISLINGTON, KENSINGTON & CHELSEA AND WESTMINSTER
BARNET, BRENT, ENFIELD, HARINGEY AND HARROW
HACKNEY, NEWHAM, TOWER HAMLETS AND WALTHAM FOREST
BARKING & DAGENHAM, HAVERING AND REDBRIDGE
EALING, HAMMERSMITH & FULHAM, HILLINGDON AND HOUNSLOW
KINGSTON, MERTON, RICHMOND AND WANDSWORTH
CROYDON, LAMBETH, SOUTHWARK AND SUTTON
BEXLEY, BROMLEY, GREENWICH AND LEWISHAM
In conversions, refurbishments and new builds, pipes, cables and ducts are run through fire-rated walls and floors, and every one leaves a gap. We seal each penetration with tested, certified systems that suit the building's construction, then photograph each seal before it is covered up.
Hidden voids behind walls, under floors and in roof spaces can carry fire unseen from one flat to the next. In older buildings, later alterations can open up new routes. We install cavity barriers in line with Building Regulations, the latest Building Control guidance and your building's fire strategy.
A fire door only works when the whole set is right, from the frame and seals to the closer. For landlords, managing agents and facilities managers, we inspect, install and maintain fire doors under our BM TRADA certification, with photo evidence for every door we check.
If you do not know the condition of your building's fire compartments, a survey is the place to start. We check walls, floors, risers and voids, find every breach and give you a clear report, plus a written price for any remedial work it uncovers.
When a fire risk assessment flags breaches, or old fire stopping no longer meets current standards, we put it right. We remove failed or non-compliant materials, reinstate them with certified systems and plan the work around residents and tenants to keep disruption to a minimum.
If you let out property in Newham, you almost certainly need a licence. The borough has licensed private rented homes since 2013, and since 2023 selective and additional licensing have covered every ward except Stratford Olympic Park and Royal Victoria. Larger HMOs need a mandatory licence everywhere.
If you plan to turn a home into a small HMO, you need planning permission first across most of the borough. Newham's Article 4 Direction has applied since July 2013. Building the fire stopping into your plans saves reopening finished walls later.
If you manage a residential block at least 18 metres or seven storeys tall with two or more homes, it is regulated by the Building Safety Regulator. Around Stratford's new towers, clear records of what was installed matter more than ever, so we photograph every seal before it is covered.

Our fire stopping, fire door installation and fire door maintenance are all third-party certified by BM TRADA. You can check the scope of each certificate in the BM TRADA certified supplier directory.
We are independent of manufacturers and other contractors. Whether it is a listed building or a modern block, our advice follows compliance and real risk, not a product we need to sell.
Each seal is photographed before it is covered. You receive installation certificates, product datasheets and as-built drawings, ready for your fire risk assessor, Building Control and insurer.
Your site survey is free, with no obligation. We explain what we find in plain English and offer a one-day turnaround on quotes, with nothing added that you have not approved.
FAQS
Yes. In new buildings, pipes, cables and ducts pass through fire-rated walls and floors in every riser and plant room. We seal each gap before the boards go up and hand over certificates and datasheets, as we did for the main contractor at Uxbridge Station.
Only if it is a larger HMO with five or more people, which needs a mandatory licence anywhere in Newham. Selective and additional licensing do not apply in those two wards, but they cover the rest of the borough. Check your address with the council, and we can give you certified fire stopping records whatever licence you need.
Yes. We install fire doors in new and refurbished blocks under our BM TRADA Q-Mark fire door installation certification, checking gaps, seals, closers and hinges so each door is right from day one. You receive a record of every door to keep with your building safety and handover files.
Yes. Conversions often run pipes and cables through floors that were never built to separate homes. We survey first, seal those gaps with tested systems, upgrade fire doors where needed and give you a photographed, certified record.
It depends on how many gaps need sealing, what passes through them, how easy they are to reach and whether the building is occupied. The survey is free with no obligation, and we offer a one-day turnaround on your written quote. Sending drawings or a fire risk assessment beforehand helps. Call 020 8798 2580 or book online.
Phone
Contact us for immediate assistance or questions.
0208 798 2580
For enquiries related to our services, please reach out.
[email protected]
CONNECT
Main contractors can send drawings or a package for pricing. Facilities managers can attach the fire risk assessment. Zak or Ryan will come back to you with a time to visit.
We use your details only to reply to this enquiry. Privacy policy